Browse Standards

IEEE Guide for Online Monitoring of Large Synchronous Generators (10 MVA and Above)
The guidelines for online monitoring of large synchronous generators are described in this guide. High-level discussions of each of the proposed monitoring methods, and recommended threshold values, whenever there is a general agreement on ...
IEEE Guide for Moisture Measurement and Control in SF6 Gas-Insulated Equipment - Redline
Guidelines for moisture level measurement, moisture data interpretation, and moisture control in gas-insulated switchgear (GIS) are provided.
IEEE Draft Recommended Practice for Sizing Nickel-Cadmium Batteries for Stationary Applications
The sizing of nickel-cadmium batteries used in standby operation for stationary applications is discussed in this recommended practice.
IEEE Recommended Practice for Installation, Maintenance, Testing, and Replacement of Vented Nickel-Cadmium Batteries for Stationary Applications - Redline
This recommended practice provides recommendations for installation design and for installation, maintenance, and testing procedures that can be used to optimize the life and performance of vented nickel-cadmium batteries, including partial...
IEEE Guide for Multifactor Stress Functional Testing of Electrical Insulation Systems
A guide for developing test procedures for the functional testing of insulation systems used in long-life electrical equipment exposed to more than one factor of influence in service is presented. Included are descriptions of technical prob...
IEEE Recommended Practice for Voltage-Endurance Testing of Form-Wound Bars and Coils
The voltage endurance testing of form-wound bars and coils for use in large rotating machines is covered.
IEEE Recommended Practice for Specifying Electric Submersible Pump Cable--Ethylene-Propylene Rubber Insulation - Redline
Minimum requirements for the design, construction, manufacturing, testing, purchasing, and application of electric submersible pump (ESP) cable are presented. The cable is round or flat, with ethylene-propylene rubber insulation, nitrile ja...
IEEE Recommended Practice for Sizing Lead-Acid Batteries for Stand-Alone Photovoltaic (PV) Systems - Redline
A method for determining the energy-capacity requirements (sizing) of both vented and valve-regulated lead-acid batteries used in terrestrial stand-alone photovoltaic (PV) systems is described in this recommended practice. Sizing batteries ...
IEEE Standard Definitions and Characterization of Floating Gate Semiconductor Arrays
Summary form only given. This standard describes the underlying physics and the operation of floating gate memory arrays, specifically, UV erasable EPROM, byte rewritable E/sup 2/PROMs, and block rewritable "flash" EEPROMs. In addition, rel...
IEEE Guide for Monitoring, Managing, and Cleaning of Contaminated Insulators
Procedures for cleaning contaminated electrical insulators (excluding nuclear, toxic, and hazardous chemical contaminants) of all types, using various equipment and techniques, are provided in this guide.