Browse Standards

IEEE Guide for Aging Mechanisms and Diagnostic Procedures in Evaluating Electrical Insulation Systems
Background information necessary for proper construction of aging mechanisms and selection of diagnostic procedures when designing tests for functional evaluation of insulation systems for electrical equipment is presented. Aging mechanisms...
(Replaced) IEEE Guide for the Statistical Analysis of Electrical Insulation Breakdown Data
This guide describes, with examples, statistical methods to analyze times to break down and breakdown voltage data obtained from electrical testing of solid insulating materials, for purposes including characterization of the system, compar...
ANSI/IEEE Std 853-1985 IEEE Recommended Practice for Voltage-Endurance Testing of Enameled Wire
IEEE Standard Procedure for the Determination of the Ampacity Derating Factor for Fire-Protected Cable Systems - Redline
A detailed test procedure is provided for determining the ampacity derating factor in the following cable installation configurations: block-out or sleeve-type cable penetration fire stops; conduits covered with a protective material; tray ...
IEEE Recommended Practice for Precision Centrifuge Testing of Linear Accelerometers - Redline
This recommended practice describes the conduct and analysis of precision tests that are to be performed on linear accelerometers using centrifuge techniques. The term “precision,” in this context, refers to tests that are conducted to ev...
IEEE Standard Power Cable Ampacity Tables Amendment 1: Revision to Introduction
Corrections to the introduction for the standard with over 3000 ampacity tables for extruded dielectric power cables rated through 138 kV and laminar dielectric power cables rated through 500 kV are addressed in this amendment.
IEEE Standard for Hydraulic Turbine and Generator Shaft Couplings and Shaft Runout Tolerances
The dimensions for all types of shaft couplings and shaft runout tolerances for hydraulic turbines and generators are included in this standard. Shafts and couplings included in this standard are used for both horizontal and vertical connec...
IEEE Technology Report on Wake-Up Radio: An Application, Market, and Technology Impact Analysis of Low-Power/Low-Latency 802.11 Wireless LAN Interfaces
The IEEE Technology Report on Wake-Up Radio provides: An overview of IEEE 802.11ba Wake-Up Radio Near- and long-term use cases Market forecasts A comparison of Wake-Up Radio to other technologies A look at potential future developments IEEE...
IEEE Guide for Designing Multistress Aging Tests of Electrical Insulation in a Radiation Environment
Guidelines for evaluating electrical insulation materials that are subjected to more than one significant aging stress are provided. The focus is on materials or equipment intended for use in nuclear facilities, such as power stations, wher...
IEEE Trial Use Guide for loading Mineral-Oil Immersed Power Transformers Rated in Excess of 100 MVA (65 Degree C Winding Rise)
This guide covers general recommendations for loading mineral-oil-immersed power transformers manufactured in accordance with ANSI/IEEE C57.12.00-1980 [1] 1 and having a maximum nameplate rating in excess of 100 MVA (three phase) or 333 MVA...