IEEE Draft Standard for Testing Faulted Circuit Indicators
Definitions, service conditions, test procedures, and test conditions for faulted circuit indicators for use on power distribution systems are established in this test code.
IEEE Recommended Practice for the Detection and Measurement of Partial Discharges (Corona) During Dielectric Tests
This document is based on IEC Publication 270-1968, Partial Discharge Measurements. adheres closely to the IEC recommendations with the following exceptions:(1) The terms partial discharge energy and partial discharge power are not used in ...
IEEE Guide for Thermal Resistivity Measurements of Soils and Backfill Materials
The measurement of thermal resistivity of soil and backfill materials to include concrete, engineered backfills, grout, rock, sand, and any other material used to encase the cable system installed in the ground is covered in this guide. A t...
IEEE Guide for the Preparation of Excitation System Specifications
This guide is intended to provide to the specification writer the information to prepare a specification for the purchase of an excitation system. This guide is presented in narrative form with descriptions of functions typical of excitatio...
IEEE Standard for Extruded and Laminated Dielectric Shielded Cable Joints Rated 2.5 kV to 500 kV - Redline
Electrical ratings and test requirements of cable joints used with extruded and laminated dielectric shielded cable rated in preferred voltage steps from 2.5 kV to 500 kV are established in this standard. In addition, test requirements for ...
IEEE Guide for Measuring Resistivity of Cable-Insulation Materials at High Direct Voltages
This guide describes the apparatus and procedures for the determination of resistivity and polarization characteristics of solid and laminar insulation specimens (considered for use in high direct-voltage power cables) at uniform temperatur...
IEEE Guide for Field Testing of Shielded Power Cable Systems Using Very Low Frequency (VLF) (less than 1 Hz) - Redline
Very low frequency (VLF) withstand and other diagnostic tests and measurements that are performed using VLF energization in the field on shielded power cable systems are described in this guide. Whenever possible, cable systems are treated ...
IEEE Guide for Field Testing of Laminated Dielectric, Shielded AC Power Cable Systems Rated 5 kV to 500 kV Using High Voltage Direct Current (HVDC)
The recommended practices and procedures for direct voltage acceptance and maintenance testing of shielded, laminated, dielectric-insulated power cable systems rated 5 kV to 500 kV are presented in this guide. It applies to all types of lam...
IEEE Guide for Field Testing and Evaluation of the Insulation of Shielded Power Cable Systems Rated 5 kV and Above - Redline
Various field test methods that are currently available for or have been developed are listed in this guide. The guide covers shielded, insulated power cable systems rated 5 kV and above. The guide also describes the tests and gives advanta...
IEEE Standard for Separable Insulated Connector Systems for Power Distribution Systems Rated 2.5 kV through 35 kV - Redline