Browse Standards

IEEE Standard for Design and Qualification of Class 1E Control Boards, Panels, and Racks Used in Nuclear Power Generating Stations
Design requirements for new and/or modified Class 1E control boards, panels, and racks are specified, and methods to verify that these requirements have been satisfied are established in this standard. Methods for meeting the separation cri...
IEEE Standard ATLAS Test Language
This standard defines ATLAS, the Abbreviated Test Language for All Systems, which offers a standardized test language for expressing test specifications and test procedures. It is a test-oriented language independent of test equipment, and ...
IEEE Guide for Planning of Preoperational Testing Programs for Class 1E Power Systems for Nuclear Power Generating Stations
Directions for establishing an acceptable pre-operational testing program for Class 1E power systems in nuclear power generating stations are provided. The pre-operational tests are performed after the appropriate construction tests have be...
IEEE Standard for Extruded and Laminated Dielectric Shielded Cable Joints Rated 2.5 kV to 500 kV - Redline
Electrical ratings and test requirements of cable joints used with extruded and laminated dielectric shielded cable rated in preferred voltage steps from 2.5 kV to 500 kV are established in this standard. In addition, test requirements for ...
IEEE Guide for Measuring Resistivity of Cable-Insulation Materials at High Direct Voltages
This guide describes the apparatus and procedures for the determination of resistivity and polarization characteristics of solid and laminar insulation specimens (considered for use in high direct-voltage power cables) at uniform temperatur...
IEEE Guide for Field Testing of DC Shielded Power Cable Systems Rated 5 kV and Above with High Direct Current Test Voltages
The recommended practices and procedures for direct voltage acceptance and maintenance testing of shielded, insulated power cable systems rated 5 kV and above for dc service are presented in this guide. It applies to all types of power cabl...
IEEE Guide for Field Testing of Shielded Power Cable Systems Rated 5 kV and Above with Damped Alternating Current (DAC) Voltage
The application of Damped ac (DAC) for field testing of power cables is described. DAC voltage withstand testing and diagnostic tests and measurements that are performed in combination with DAC voltage application in the field on shielded p...
IEEE Guide for Partial Discharge Field Diagnostic Testing of Shielded Power Cable Systems
The diagnostic testing of new or service-aged, installed shielded power cable systems, which include cable, joints, and terminations, using electrical partial discharge (PD) detection, measurement, and location is covered by this guide. PD ...
IEEE Guide for Field Testing of Shielded Power Cable Systems Using Very Low Frequency (VLF) (less than 1 Hz) - Redline
Very low frequency (VLF) withstand and other diagnostic tests and measurements that are performed using VLF energization in the field on shielded power cable systems are described in this guide. Whenever possible, cable systems are treated ...
IEEE Guide for Field Testing of Laminated Dielectric, Shielded AC Power Cable Systems Rated 5 kV to 500 kV Using High Voltage Direct Current (HVDC)
The recommended practices and procedures for direct voltage acceptance and maintenance testing of shielded, laminated, dielectric-insulated power cable systems rated 5 kV to 500 kV are presented in this guide. It applies to all types of lam...