IEEE Standard Performance Characteristics and Dimensions for Outdoor Apparatus Bushings
Superseded by C57.19.01-2000 Electrical, dimensional, and related requirements for outdoor power-class apparatus bushings that have basic impulse insulation levels of 110 kV and higher are covered. Specific values for dimensional and relate...
IEEE Guide for the Application of Interrupter Switches to Switch Capacitance Loads
Usual Temperature and Altitude Service Conditions-Equipment conforming to this Standard shall be suitable for operation at its standard rating, provided that:(a) The temperature of the cooling air (ambient temperature) does not exceed 40C i...
AIEE Standard for Air Switches, Insulator Units, and Bus Supports (Supersedes AIEE No 22- 1942 and 22A- 1949)
This standard applies to the following types of devices designed for operation above 600 volts whether for indoor or outdoor service. Air switches such as disconnecting, grounding, etc., for manual or automatic operation. Air interrupter sw...
IEEE General Requirements and Test Procedure for Outdoor Apparatus Bushings
This standard applies to outdoor power class apparatus bushings which have basic impulse insulation levels of 100 kV and above for use as components of oil-filled transformers, oil-filled reactors, and oil circuit breakers.
AIEE Proposed Standard for Low-Voltage Air Circuit Breakers (Published for one year trial use)
This standard applies to all air circuit breakers with interrupting rating over 10,000 amperes as follows: A. Air circuit breakers 1500 volts or less alternating current and 3000 volts or less direct current. Special purpose air circuit bre...
AIEE Standard for Low-Voltage Air Circuit Breakers (and Application Guide)
This standard applies to all air circuit breakers with interrupting rating over 10,000 amperes as follows: A. Air circuit breakers 1500 volts or less alternating current and 3000 volts or less direct current. Special purpose air circuit bre...
AIEE Standards for Alternating Current Power Circuit Breakers
These standards apply to all indoor and outdoor types of alternating-current power circuit breakers rated in excess of 600 volts.
IEEE Draft Standard for Shunt Power Capacitors
Power capacitors rated 216 V or higher, 2.5 kvar or more, and designed for shunt connection to alternating-current transmission and distribution systems operating at a nominal frequency of 50 Hz or 60 Hz are considered.
IEEE Standard for Electrical and Electronic Control Apparatus on Rail Vehicles - Redline
A set of uniform design, application, and test requirements for electrical and electronic control apparatus on rail vehicles is provided in this standard.
AIEE American Standard for Industrial Control Apparatus