AIEE Revised Report on Standards for Valve and Expulsion Type Lightning Arresters
IEEE Standard for Surge Arresters for AC Power Circuits
This standard applies to surge-protective devices designed for repeated limiting of voltage surges on 50 Hz or 60 Hz power circuits by passing surge discharge current and subsequently automatically interrupting the flow of follow current. T...
AIEE Standards for Switchgear Assemblies
These standards cover assemblies of switchgear devices such as switches, interrupting devices, control, metering, protective and regulating equipment with associated interconnections and supporting structures. These standards do not apply t...
AIEE Automatic Stations
AIEE Standards for Fuses Above 600 Volts
This Standard applies to the following types of devices designed for operation above 600 volts whether for indoor or outdoor service. (a) Fuses (see paragraph 25-50). (b) Fuse cutouts (see paragraph 25-64). (c) Fuse parts of combined equipm...
IEEE Standard Performance Characteristics and Dimensions for Outdoor Apparatus Bushings
Superseded by C57.19.01-2000 Electrical, dimensional, and related requirements for outdoor power-class apparatus bushings that have basic impulse insulation levels of 110 kV and higher are covered. Specific values for dimensional and relate...
IEEE Guide for the Application of Interrupter Switches to Switch Capacitance Loads
Usual Temperature and Altitude Service Conditions-Equipment conforming to this Standard shall be suitable for operation at its standard rating, provided that:(a) The temperature of the cooling air (ambient temperature) does not exceed 40C i...
AIEE Standard for Air Switches, Insulator Units, and Bus Supports (Supersedes AIEE No 22- 1942 and 22A- 1949)
This standard applies to the following types of devices designed for operation above 600 volts whether for indoor or outdoor service. Air switches such as disconnecting, grounding, etc., for manual or automatic operation. Air interrupter sw...
IEEE General Requirements and Test Procedure for Outdoor Apparatus Bushings
This standard applies to outdoor power class apparatus bushings which have basic impulse insulation levels of 100 kV and above for use as components of oil-filled transformers, oil-filled reactors, and oil circuit breakers.
AIEE Proposed Standard for Low-Voltage Air Circuit Breakers (Published for one year trial use)
This standard applies to all air circuit breakers with interrupting rating over 10,000 amperes as follows: A. Air circuit breakers 1500 volts or less alternating current and 3000 volts or less direct current. Special purpose air circuit bre...