IEEE Recommended Practice for Sizing Stand-Alone Photovoltaic (PV) Systems - Redline
Provided in this recommended practice is information to assist in sizing the array and battery of a stand-alone photovoltaic (PV) system. Systems considered in this recommended practice consist of PV as the only power source and a battery f...
IEEE Recommended Practice for Interconnecting Distributed Resources with Electric Power Systems Distribution Secondary Networks
Recommendations and guidance for distributed resources (DR) interconnected on the distribution secondary networks, including both spot networks and grid networks, are provided. This document gives an overview of distribution secondary netwo...
IEEE Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces--Amendment 1: To Provide More Flexibility for Adoption of Abnormal Operating Performance Category III
The performance and functional capability requirements for DER connected with the Area Electric Power Systems (Area EPS) are defined in IEEE Std 1547(TM). This amendment revises the ranges of allowable trip clearing time settings in Table 1...
IEEE Recommended Practice for Testing the Performance of Stand-Alone Photovoltaic Systems
Tests to determine the performance of stand-alone photovoltaic (PV) systems and for verifying PV system design are presented in this recommended practice. These tests apply only to complete systems with a defined load. The methodology inclu...
IEEE Standard for Measurement and Limits of Voltage Fluctuations and Associated Light Flicker on AC Power Systems - Redline
Background information on supply voltage fluctuations caused by fluctuations in power demands of installations is provided by this standard. The manifestation of these supply voltage fluctuations as lamp flicker is presented in this standar...
IEEE Guide for Selection of Valve-Regulated Lead-Acid (VRLA) Batteries for Stationary Applications - Redline
This guide describes methods for selecting the appropriate type of valve-regulated, immobilized-electrolyte, recombinant lead-acid battery for any of a variety of stationary float applications. The purpose of this document is to ensure that...
IEEE Recommended Practice for Sizing Lead-Acid Batteries for Stand-Alone Photovoltaic (PV) Systems - Redline
A method for determining the energy-capacity requirements (sizing) of both vented and valve-regulated lead-acid batteries used in terrestrial stand-alone photovoltaic (PV) systems is described in this recommended practice. Sizing batteries ...
IEEE Standard for Specifying and Testing Single-Axis Interferometric Fiber Optic Gyros - Redline
Specification and test procedures for a single-axis interferometric fiber optic gyro (IFOG) for use as a sensor in attitude control systems, angular displacement measuring systems, and angular rate measuring systems are defined. The test pr...
IEEE Recommended Practice for Installation and Maintenance of Lead-Acid Batteries for Photovoltaic (PV) Systems - Redline
Design considerations and procedures for storage, location, mounting, ventilation, assembly, and maintenance of lead-acid storage batteries for photovoltaic power systems are provided in this standard. Safety precautions and instrumentation...
IEEE Standard for Local and Metropolitan Area Networks - Part 15.7: Short-Range Optical Wireless Communications Amendment 1: Higher Rate, Longer Range Optical Camera Communication (OCC)
The existing OCC physical layer of IEEE Std 802.15.7-2018 is amended with one PHY specification for a higher rate and longer range.